piD-TECH® Plus Plug-In Photoionization Sensor
![]() |
The piD-TECH® Plus Plug-In photoionization sensor is designed to be installed in portable and stationary gas monitors that accept City TechnologyTM4P cells. It provides complete photoionization detection capability in a package that has the same dimentional and electrical profile as these cells.
|
![]() |
NEW RELEASE The piD-TECH plus White Sensor with a 9.6eV lamp! Available in gains of 10, 100, and 1000. |
Application Note - Total Volatile Organic Compound Measurement
piD-TECH® Plus - Performance Characteristics
| Target Gases: | VOC's & other gases with ionization potentials <10.6eV. An ionization potential list is available upon request |
| Lamp Energy: | 10.6eV |
| T90Response Time: | < 20 secconds, diffusion mode |
| Power Consumption: | 64mW to 300mW dependent on supply voltage |
| Power Voltage: | 3.2 to 10.0 VDC |
| Onboard filter: | To remove liquids/particles |
| Temperature Range: | -20°c to 40°c |
| Relative Humidity Range: | 0 to 90% non-condensing |
| Humidity Response: |
<1ppm @ 90% RH, 25°c |
| Expectived Operating Life: | >1 year |
Physical Characteristics
| Package Type: | City TechnologyTM4P |
| Weight: | < 8g (approx.) |
| Position Sensitivity: | None |
| Certifications: | USA: UL 913, Class I, Division 1, Groups A,B,C,D Europe: ATEX directives EN50014 and EN50020 II G Eex ia IIC Tamb -20C to +60C IECEx Standards IEC60079-0 and IEC60079-11 Ex ia IIC Tamb =-20C to +60C |
| Warranty Period: | 18 months from date of shipment or 12 months from date of installation, which ever comes first |
| Lamp Replacement: | Lamps are replaced by a cell exchange program |
.jpg)
.jpg)