Model 8800 PID Total Volatile Organic Vapor Analyzer
![]() |
The Model 8800 PID has a photoionization detector (PID) and an incredible dynamic range from 10 ppb to 1%. It is designed to analyze hundreds of volatile organic compounds (VOCs) and various other gases. The analyzer is relatively humidity insensitive and can be configured with internal components for a single or multipoint analysis of noncondensing gas samples.
|
Data Sheet - English
Data Sheet - Chinese
Request A Quote
Model 8800 PID Analyzer - Product Specification
| Sampling: | Internal single or multipoint modules, with or without sample pump(s), for prefiltered (< or = .1 microns), non-condensing samples |
| Calibration: | Programmable automatic, or manual (with internal selection valves) |
| Detector: | Photoionization detector (PID) |
| Lamp: | Energies: 10.6 eV (life span >6000 hrs), 11.7 eV (life span approximately 140 hrs). |
| MDQ: | Minimum detectable quantity: <0.1 ppm (as isobutylene), <0.1 ppm (as benzene). |
| Quenching: | Signal quenching due to moisture:< 30% at 95% R.H. and 23° Celsius. |
| Range: | Analog - Virtual range with software selectable endpoints provides full-scale ranges from 1.0 ppm - 1% (as isobutylene) Digital - Display auto-ranges from 0.01 ppm to 1% (as isobutylene) |
| Linearity: | Linear range: 0 - 10,000 ppm (isobutylene). Accurate to ± 1 ppm or ± 15% of reading, whichever is greater. |
| Drift: | Sample dependent. Zero:< 0.1 ppm (as isobutylene) over 24 hours. Span: 100 ppm isobutylene,< 3 % over 24 hours. |
| Response Time: | Isobutylene:< 6 Seconds to 90% of final reading |
| Output: | Analog - 1 (standard) to 15 programmable 0-20 mA or 4-20 mA loop power supplied, isolated outputs or optional 0-1 V, 0-5 V, or 0-10 V isolated outputs. Selectable for concentration, temperature, flow (fuel, air, or sample). Digital - Standard: RS-485 output (RS-232 option). |
| Relays: | 5 (standard) to 15 programmable (latched/not, NO/NC) contact closures (1A@30V max). Selectable for alarm thresholds or events (calibration, fault, or sample location). |
| Alarms: | Multilevel concentration, average concentration, and fault Audible - Horn: Sounducer, generating 85 dB @10 cm. Selectively en-/disabled for keypad input, fault, and alarms. |
| Physical: | Dimensions: 19.00" W x 16.00" D x 8.75" H (48.26 cm W x 40.64 cm D x 22.23 H). Nominal weight: 30 lb (13.64 kg). |
| Configuration: | Bench-top or rack-mount (19" panel) |
| Display: | Digital vacuum fluorescent, 20 characters x 2 lines |
| Power: | 90-120 VAC or optional 210-230 VAC, 50-60 Hz |
| Operating Conditions: | Temperature: 32-104 °F (0-40 °C). Humidity: 0-95%, non-condensing. |
| Gas Specifications: | Span - Isobutylene, or as required by application Connections - 1/4" O.D. Tube fitting connectors (1/8", 4 mm, and other options) |
Model 8800 PID Analyzer - Options & Accessories
| Samplers: | Internal multipoint module, with or without internal sample pump(s), available in 4-point or 8-point configurations |
| Enclosures: | General purpose, X-purged or Z-purged |
| Expansion Boards: | Analog - Provides 4 or 10 additional programmable 4-20 mA outputs, with sample read & hold Relay - Provides up to 10 additional programmable relays |
| Calibration Gas: | Zero and span gases for a variety of applications |