Model 8800 A Total Hydrocarbon Analyzer

The Model 8800 A is based on a flame ionization detector (FID) and has a dynamic range from less than 10 ppb to 100%. The analyzer has a generous complement of analog, digital, and logic output capabilities with room to expand. It can be configured with internal components for a single or multipoint analysis of non-condensing gas samples.

  • Automatic calibration
  • Electronic flow control of fuel, air, and sample
  • Programmable virtual analog ranges
  • Programmable relays
  • Automatic FID ignition

Data Sheet - English
Data Sheet - Chinese
Request A Quote


Model 8800 A Analyzer - Product Specification

Sampling: Internal single or multipoint modules, with or without sample pump(s) for prefiltered (< or = .1 microns), non-condensing samples
Detector: Flame ionization detector (FID)
Calibration: Programmable automatic, or manual (with internal selection valves)
MDQ: Minimum detectable quantity: 0.01 ppm (10 ppb).
Range: Analog - Virtual range with software selectable endpoints provides full-scale ranges from 1.0 ppm to over 50% (as methane)

Digital - Display auto-ranges from 0.01 ppm (10 ppb) to over 50% (as methane)
Repeatability: ± 1% Full-scale response
Drift: ± 1% Over 24 hours
Response Time: < 5 Seconds to 90% of final reading
Display: Digital vacuum fluorescent, 20 characters x 2 lines
Output: Analog - 1 (standard) to 15 analog 0-20 mA or 4-20 mA loop power supplied, isolated outputs. Selectable for concentration, temperature, flow (fuel, air, or sample).

Digital - Standard: RS-485 output (RS-232 option).
Relays: 5 (standard) to 15 programmable (latched/not, NO/NC) contact closures (1A@30V max).  Selectable for alarm thresholds or events (calibration, fault, or sample location).
Alarms: Multilevel concentration, average concentration, and fault

Audible - Horn: Sounducer, generating 85 dB @10 cm. Selectively en-/disabled for keypad input, fault, and alarms.
Physical: Dimensions: 19.00" W x 16.00" D x 8.75" H (48.26 cm W x 40.64 cm D x 22.23 H). Nominal weight: 30 lb (13.64 kg).
Configuration: Bench-top or rack-mount (19" panel)
Gas Specifications: Support - Hydrocarbon content:<1 ppm required. Air @ approx. 200 cc/min, hydrogen @ approx. 40 cc/min. (Options: H2/N2 or H2/He @ 100 cc/min.)

Connections - 1/4" O.D. Tube fitting connectors (1/8", 4 mm, and other options)
Power: 90-120 VAC or optional 210-230 VAC, 50-60 Hz
Operating Conditions: Temperature: 32-104 °F (0-40 °C). Humidity: 0-95%, non-condensing.

Model 8800 A Analyzer - Options & Accessories

Samplers: Internal multipoint modules, with or without sample pump(s) available in 4-point or 8-point configurations
Enclosures: General purpose, Wallmount, X-purged or Z-purged
Expansion Boards: Analog - Provides up to 10 additional programmable 4-20 mA outputs, with sample read & hold

Relay - Provides up to 10 additional programmable relays
Catalysts: Methanizer for low-level CO/CO2 analysis
Oxidizer for methane only analysis
Gas Generators: Zero air or hydrogen
Calibration Gas: Zero and span gases for a variety of applications